Skip to content
PT Premium Coconut Shisha Charcoal Indonesia

How to read a charcoal COA, line by line

By Agus Setiawan, Production Supervisor · Reviewed by Budi Santoso, Factory Manager, · Last updated

Five sections, in the order they appear on most certificates: the header, the method column, the results table, validity and the signature. Read down a certificate alongside.

Moisture balance bench
Moisture content is determined gravimetrically: a weighed sample is dried to constant mass and the loss is reported as a percentage of the original weight.

1 · The header

Three things to find: the certificate number, the dates (received and tested are usually separate lines, and can differ by a day or more), and the holder — the company the sample was submitted for.

The holder line is the check most buyers skip and the one that catches the most. A report naming a different company than the seller is a trading house passing through someone else's document.

What you check is that the entity on the report is the entity you are buying from. A laboratory addresses its report to the registered entity, so the address on it need not match the yard in the photographs.

A supplier who can explain a discrepancy on their own paperwork is in a different position from one who cannot — that is what the check is for. We do not publish a laboratory report yet; when we do, it is listed in our document library.

2 · The method column

Look for a method against each row, not one method for the certificate. Different rows can carry different methods — a published standard for some, the laboratory's own procedure for others.

A named laboratory in-house method is not a red flag. Accredited laboratories validate their own procedures under their ISO/IEC 17025 scope, and an in-house method with a reference number is a documented, auditable thing you can ask about. An unstated method is the red flag. A percentage with nothing beside it cannot be compared with any other supplier's percentage, and that is the comparison you are trying to make.

Moisture check at the line
Moisture is checked at the line rather than only in a laboratory, because a batch that leaves the dryer wet cannot be corrected once it is packed.

3 · The results table — and its basis

Four rows on a proximate analysis: moisture, ash, volatile matter, fixed carbon. Before reading any of them, find the basis — as received, or dry. The same material reports different numbers on each, and a figure compared across bases is not a comparison.

Then run the arithmetic: the four should add to about 100. Why that works, and what it means when it does not, is on fixed carbon and volatile matter.

4 · Validity

The certificate states its own validity period. Past it, the document is a historical record. It has not become false; it has simply stopped describing anything you are about to receive.

5 · The signature

A named signatory and a role. This is what makes the report attributable — and it is the line that makes the final check possible: contact the laboratory directly, quote the certificate number, and ask them to confirm it. Do not take a seller's transcription of a figure for the figure.

Cutting and sizing
Extruded lengths are cut to size after forming, which is how one die produces several catalogue sizes — for example the finger range at 35 mm and 50 mm lengths.

Red flags, and the one that is not

What you see Why it matters
"Typical" values instead of a batch number A certificate identifies the material it tested. A column headed "typical" is a specification sheet wearing a laboratory's layout.
No signature and no named signatory An unsigned report is a draft or a template. The signature is what makes it attributable to somebody at the laboratory.
Every result sitting exactly on the limit Real measurements scatter. Four figures landing precisely on four contractual limits is a pattern worth asking about.
No method stated for any row Without a method, a percentage cannot be compared with anyone else's percentage. This is the absence that actually matters.
No validity or issue date A COA describes a moment. Undated, it cannot be placed against your shipment at all.

Red-flag conventions above are generic industry practice as observed in trade and laboratory documentation, August 2026. They are heuristics for asking a better question, not grounds for rejecting a shipment.

Once you can read one

The next question is what it covers — what a certificate of analysis proves, and what it does not — and how to use it on a reorder: the reorder QC checklist.